69 Electra Convertible Top Trouble

Discussion in 'The ragtop shop' started by onemansgarbage, Apr 10, 2011.

  1. onemansgarbage

    onemansgarbage I'll take it!

    My top motor runs for 30 seconds or so and then stops. After 30 seconds or so it runs again.

    I changed the motor last year because of this problem and the new motor does the same thing.

    Now that it's getting warmer I am ready to mess with it again. I took the back seat and well liner out this morning. After the motor shuts down it is cool to the touch.

    Hopefully someone has an idea what the problem is.:pray:
     
  2. bhambulldog

    bhambulldog 1955 76-RoadmasterRiviera

    Maybe, this will help.
    I had a '73 Olds 88 Conv. My Dad had a '75 Olds 88 conv.
    They each, had on the fuse block; A rectangular circuit breaker. upon overload the circuit breaker would trip. After the breaker cooled off; the breaker would reset itself. The breaker was on the circuit for; the windows and top.
     